Difference between revisions of "HIDS 18602"

From Atomicorp Wiki
Jump to: navigation, search
(Created page with "{{Infobox |header1 = Rule 1 |label2 = Status |data2 = Active |label3 = Alert Message |data3 = Windows System Event }} = Description = Composite rule identified multiple W...")
 

Latest revision as of 12:10, 21 October 2020

Rule 1
Status Active
Alert Message Windows System Event

Contents

[edit] Description

Composite rule identified multiple Windows System Event ID 7038. This indicates that a service was unable to log on with the currently configured password multiple times. Frequency 10 / 240s

[edit] What you should do

This could be an indicator of an attack. Identify if this application is actually being accessed by an invalid / unknown source, or if this is a condition caused by a password/account that has expired or changed.


[edit] Troubleshooting

[edit] False Positives

If an application has cached an invalid/expired password this event could be triggered.

[edit] Tuning Guidance

There is no guidance for tuning this rule, this is a generic Windows error and the rule should not be disabled.

[edit] Additional Information

[edit] Support

If you are unsure about how to respond to this alert, please contact Atomicorp support. We're here to help you!

[edit] Similar Rules

None.

[edit] Knowledge Base Articles

None.

[edit] Outside References

None.

[edit] Notes

Personal tools